Kawasaki EX400 / Ninja 400 2020

21175-1332

ECU P/N21175-1332
Calibration IDKLL1KPU0
Model years2020
Compatible BIN size512 KB (524,288 bytes)

€70.00

You receive: XDF definition for TunerPro

File reference & categories
SKU:
21175-1332 KLL1KPU0

Description

This XDF definition is for Kawasaki EX400 / Ninja 400 (2020).

Calibration ID: KLL1KPU0
ECU part number: 21175-1332

to check for an exact reference match before choosing a definition.

ECU Settings — Patches & Values

Options included in this XDF definition.

Patches & switches

  • Disable MAP vs RPM [True / False]
  • Decel Fuel Cut [Enable / Disable]
  • USB / ECT Error [Enable / Disable]
  • Stock O2 [Enable / Disable]
  • Evap Purge Valve
  • Air Switching Valve

Adjustable values & tables

  • Fan Temps / limitL [1]F
  • Fan Temps / limitL [2]F
  • Fan Temps / limitH [1]F
  • Fan Temps / limitH [2]F

ECU Definition Preview

  • Fuel
    • TPS vs RPM
      • TPS Cyl1 Sw1 (50×30)
      • TPS Cyl2 Sw1 (50×30)
      • TPS Cyl1 Sw2 (50×30)
      • TPS Cyl2 Sw2 (50×30)
      • Primary Inj. Adv. (17×10)
    • MAP vs RPM
      • MAP Cyl1 Sw1 (50×30)
      • MAP Cyl2 Sw1 (50×30)
      • MAP Cyl1 Sw2 (50×30)
      • MAP Cyl2 Sw2 (50×30)
    • Ram-Air Comp
      • Gear1 (1×15)
      • Gear2 (1×15)
      • Gear3 (1×15)
      • Gear4 (1×15)
      • Gear5 (1×15)
      • Gear6 (1×15)
    • Water Temp Correction
      • Neutral (20×14)
      • In Gear (20×14)
  • Ignition
    • IGN Advance
      • IGN Gear N (50×30)
      • IGN Cyl1 Sw1 (50×30)
      • IGN Cyl2 Sw1 (50×30)
      • IGN Cyl1 Sw2 (50×30)
      • IGN Cyl2 Sw2 (50×30)
    • Volt→Dwell
      • Volt→Dwell (18×9)
  • Idle Control
    • Target Idle vs Water Temp (1×14)
  • ECU Settings
    • Fan Temps
      • Fan Temps / limitL [1]
      • Fan Temps / limitL [2]
      • Fan Temps / limitH [1]
      • Fan Temps / limitH [2]
    • Switches
      • Disable MAP vs RPM [True / False]
      • Decel Fuel Cut [Enable / Disable]
      • USB / ECT Error [Enable / Disable]
      • Stock O2 [Enable / Disable]
      • Evap Purge Valve
      • Air Switching Valve
  • MotoBINXDF.com
    • Definition information
View all maps & axes 24 tables

Table names, dimensions and units from this XDF.

Map / groupSizeX axis / unitY axis / unitValue unit
TPS Cyl1 Sw1Fuel / TPS vs RPM50 × 30———
TPS Cyl2 Sw1Fuel / TPS vs RPM50 × 30———
TPS Cyl1 Sw2Fuel / TPS vs RPM50 × 30———
TPS Cyl2 Sw2Fuel / TPS vs RPM50 × 30———
Primary Inj. Adv.Fuel / TPS vs RPM17 × 10———
MAP Cyl1 Sw1Fuel / MAP vs RPM50 × 30———
MAP Cyl2 Sw1Fuel / MAP vs RPM50 × 30———
MAP Cyl1 Sw2Fuel / MAP vs RPM50 × 30———
MAP Cyl2 Sw2Fuel / MAP vs RPM50 × 30———
Gear1Fuel / Ram-Air Comp1 × 15———
Gear2Fuel / Ram-Air Comp1 × 15———
Gear3Fuel / Ram-Air Comp1 × 15———
Gear4Fuel / Ram-Air Comp1 × 15———
Gear5Fuel / Ram-Air Comp1 × 15———
Gear6Fuel / Ram-Air Comp1 × 15———
NeutralFuel / Water Temp Correction20 × 14———
In GearFuel / Water Temp Correction20 × 14———
IGN Gear NIgnition / IGN Advance50 × 30———
IGN Cyl1 Sw1Ignition / IGN Advance50 × 30———
IGN Cyl2 Sw1Ignition / IGN Advance50 × 30———
IGN Cyl1 Sw2Ignition / IGN Advance50 × 30———
IGN Cyl2 Sw2Ignition / IGN Advance50 × 30———
Volt→DwellIgnition / Volt→Dwell18 × 9———
Target Idle vs Water TempIdle Control1 × 14———
BIN IDENTIFICATION

Automatically Find the Correct XDF

Select a .bin file to check for an exact reference match. Your file stays on your device; only its fingerprint and size are compared.

No file selected · Maximum 16 MiB

Your file stays on your device. Maximum 16 MiB.